What Delayed Ignition Bang means on your Dacor range (dacor range delayed ignition bang)
Your range will never display a code for this, because Dacor publishes none — this is the symptom itself. — no F-code or C-code covers cooktop or oven burner ignition behavior at all, since burners on a gas range typically operate on their own mechanical gas-valve and spark-ignition hardware separate from the ERC or main PBA electronics that generate those codes. A delayed ignition, where gas flows for a moment before the burner catches with an audible “whoomph,” is one of the more important gas-appliance symptoms to take seriously, since it means unburned gas accumulated briefly before ignition.

Symptoms
Read these against your range: they are what tells Delayed Ignition Bang apart from the other things that can go wrong on a Dacor range.
- A distinct delay between turning the knob and the burner actually lighting, followed by a noticeable bang or whoomph.
- A brief but noticeable gas smell in the moment just before ignition.
- The flame appears larger or more erratic than normal for the first second or two after lighting.
- The delay seems to worsen over repeated uses of the same burner.
- Other burners on the range ignite immediately and normally, isolating the issue to one position.
Common causes
On a range, Delayed Ignition Bang is a symptom of several possible problems rather than one, and narrowing it down before a range part is ordered is the whole job.
- Clogged burner ports — partial blockage slows gas reaching the igniter, letting gas build up before ignition catches.
- Weak or misaligned igniter spark — a spark that is too weak or positioned incorrectly delays catching the accumulated gas.
- Moisture on the burner assembly — dampness can delay spark ignition even with normal gas flow.
- Gas pressure irregularity — an issue with the gas supply itself rather than the burner hardware.
- Misaligned burner cap or grate — disrupted airflow around the burner can affect how quickly ignition catches.
Troubleshooting steps you can try
Before booking a visit for Delayed Ignition Bang, work through these on your range — a good share of these range calls resolve right here.
- Stop using the affected burner until it has been checked, since repeated delayed ignition is a genuine safety concern.
- Ventilate the kitchen well before attempting to use the burner again.
- Clean the burner cap, base, and ports thoroughly, since blockage is the most common and easiest cause to rule out.
- Compare ignition behavior against other burners on the same range to confirm the issue is isolated.
- Do not attempt to adjust gas pressure or ignition timing components yourself.
Parts a technician may replace
A technician will work through the burner igniter, gas valve, burner port, and ignition timing components on your range. Genuine OEM or trusted-supplier parts are matched to the range by model and serial number rather than fitted to a range on spec.
When to call a technician
Delayed ignition with an audible bang is a High-severity gas safety symptom — stop using the burner and book a technician promptly rather than continuing to use it and hoping it clears. With a High-rated problem, continuing to run the range risks turning a repairable range into a replaceable one. The technicians who will see your range are ours, not Dacor’s, and their labor is covered for 30 days.
Related help and Dacor resources
Still seeing the Delayed Ignition Bang condition on the range? Schedule a range visit, or work through our other range problem pages. www.dacor.com has the factory data for your range.