These Dacor range power board failures — F14, F15, and F95 — all appear on the Legacy ER30D/ER36D/ER48D range platform, each documented in the range’s technical manual as pointing to the identical underlying component: a defective power board.
Why three separate codes point at one part
F14, F15, and F95 are each triggered through a different diagnostic path within the range’s control logic, but the manual’s stated remedy for all three is the same: the power board itself needs replacing. This reflects that the power board handles several distinct functions on this platform, and different kinds of failure within it can surface through different problem-detection routines, even though the fix converges on the same component.
What distinguishes F14 from F15
Both are documented identically as a defective power board, both High severity, and no further distinction beyond the code number itself is given in the source documentation. In practice, this means either code should be read as equally serious and equally pointing toward the same repair, rather than trying to infer a meaningful difference between them from the numbering alone.
Why F95 sits separately in the list
F95 sits at the very top of this platform’s extended F-code range, well past the F10-through-F32 component-level problems, yet resolves to the identical power-board replacement as F14 and F15. This is a reminder that code numbering on the ER30D/36D/48D platform does not track severity or component in a simple ascending order — a high number does not necessarily mean a more exotic or more serious problem than a lower one.
Why this matters before ordering parts
Because all three converge on the same component, confirming any one of F14, F15, or F95 is enough to know a power-board replacement is the documented repair path — there is no need to distinguish further between them for parts-ordering purposes, only to confirm the exact range model so the correct board part number is sourced.
What else can look similar but is not this problem
F2, documented separately on this platform, flags a communication problem between the control panel and relay board rather than the power board itself — a related but distinct component from what F14, F15, and F95 point to. Confirming the exact code rather than assuming from symptoms alone avoids conflating these two different repairs.
When to book service
Any of F14, F15, or F95 is a power-board-level repair, a meaningful job worth scoping with an experienced technician who can confirm the board part number for your specific range model before the visit. Our range error codes page lists this full table, and our range appliance page covers current and Legacy models. Schedule a visit with the exact code and model ready, and see Dacor’s own site for current range specifications.